Complete maintenance and compliance checklist for Singapore data centres covering SCDF fire safety, SS 564 energy efficiency, BCA Green Mark, NEA cooling tower regulations, and MOM workplace safety. Ensure uptime and regulatory compliance.

No email required
Printable format
Updated Feb 2026

The Multi-Agency Compliance Challenge

Singapore data centre operators must coordinate with SCDF, BCA, MOM, NEA, EMA, and IMDA. With the data centre moratorium and strict energy efficiency requirements, compliance has never been more critical.

S$500K+
downtime cost per hour
Singapore data centers face significant financial impact from unplanned outages
6+ agencies
regulatory coordination
SCDF, BCA, MOM, NEA, EMA, IMDA - complex multi-agency compliance requirements
S$50K+
fire safety violation fine
serious violations under Fire Safety Act, plus potential operating restrictions
Moratorium
on new data centers
strict energy efficiency requirements under BCA Green Mark for new facilities

This checklist helps you stay organized. See how to automate it with Infodeck.

Complete Compliance Checklist

Use this checklist to ensure your data centre meets SCDF, BCA, MOM, NEA, and EMA requirements. Click any section to expand or collapse.

Fire Safety Certification

Fire Detection Systems (SS 545)

Fire Suppression Systems

Emergency Systems & Egress

Licensed Electrical Work

Power Distribution

UPS Systems

Backup Generators

Precision Air Conditioning

Chilled Water Systems

Cooling Towers (NEA Regulated)

Environmental Monitoring

Access Control

Surveillance Systems

Perimeter & Building Security

Generator Emissions

Refrigerant Management

Hazardous Materials

General WSH Requirements

Electrical Safety

First Aid & Emergency

Confined Space & Working at Height

Structural & Building

Lift & M&E Systems

Structured Cabling

Containment & Raised Floor

Total inspection items: 150+ tasks across 7 compliance categories
Print this checklist
Smart Automation

Where Sensors Can Do the Work for You

Data centre compliance is ideal for IoT automation - continuous environmental monitoring for SS 564, PUE tracking for BCA Green Mark, and cooling system optimization can all be automated 24/7 with real-time alerts.

Environmental Monitoring

Server inlet points
SS 564
Real-time temperature monitoring (18-27C range) with automated alerts
Hot aisle containment
SS 564
Return air temperature optimization for PUE improvement
Under-floor plenum
Best practice
Pressure differential monitoring for airflow optimization
All zones
SS 564
Humidity monitoring (40-60% RH) with control integration

Power Infrastructure

UPS systems
SS 564
Battery health, load percentage, and runtime monitoring
PDUs
SS 564
Per-circuit power monitoring for BCA Green Mark reporting
Generators
Fire Code
Fuel level, battery voltage, and run-hour tracking
Main switchgear
SS 638
Power quality and thermal monitoring

Cooling Infrastructure

CRAC/CRAH units
SS 553
Supply/return temps, filter pressure, and runtime hours
Chillers
BCA Green Mark
kW/RT efficiency monitoring for Green Mark compliance
Cooling towers
NEA EPHA
Water quality, conductivity, and Legionella risk monitoring
Under-floor/ceiling
Best practice
Water leak detection and overflow prevention

Fire & Safety

Clean agent cylinders
Fire Code
Pressure monitoring with low-pressure alerts
VESDA systems
SS 545
Smoke particle trending and threshold alerts
Water detection
Best practice
Under-floor and ceiling water leak detection
Fuel tanks
NEA/SCDF
Level monitoring and leak detection
Implementation Guide

Set Up Compliance Tracking in Infodeck

Follow these steps to automate your data centre's compliance program. Each inspection from the checklist above becomes a scheduled, tracked, and documented task.

1

Create Recurring Work Orders by Frequency

Group compliance tasks by frequency and create recurring work orders. Infodeck auto-generates them on schedule.

Weekly: Generator Test
Fire Code compliance
Monthly: Fire Alarm Test
SS 545 requirement
Annual: FSC Renewal
SCDF licensed contractor
2

Connect IoT Sensors for Continuous Monitoring

Temperature sensors for SS 564 compliance (18-27C), power meters for PUE tracking, and cooling tower monitors for NEA compliance. Smart Workflows create work orders when thresholds are exceeded.

IF server inlet temp > 27C then Create work order and Alert NOC team
3

Generate Audit-Ready Reports

When SCDF, BCA, or NEA officers arrive, export complete compliance history with one click. All inspections, PUE readings, and corrective actions documented for regulatory audits and BCA Green Mark certification.

Ready to Automate Data Centre Compliance?

Get the printable checklist now, or start automating your compliance tracking with Infodeck's 30-day free trial.

Free Resource

Download Checklist

Print / Save PDF

No email required

Start Automating

Try Infodeck Free

Start Free Trial

30 days free, no credit card

Want a personalized demo for your data centre operation?

Book a Demo

Regulatory Sources

Disclaimer

This checklist is provided as a general guide for Singapore data centre compliance based on the sources cited above. Requirements may vary based on facility type, capacity, and specific conditions. Always verify specific requirements with SCDF, BCA, MOM, NEA, EMA, and other relevant authorities.

Last updated: February 2026 | Region: Singapore